{"id":721,"date":"2026-05-03T19:26:43","date_gmt":"2026-05-03T19:26:43","guid":{"rendered":"https:\/\/www.eliteblocc.com\/staging.v2\/?page_id=721"},"modified":"2026-05-19T10:17:27","modified_gmt":"2026-05-19T10:17:27","slug":"system-assembly","status":"publish","type":"page","link":"https:\/\/www.eliteblocc.com\/staging.v2\/system-assembly\/","title":{"rendered":"System Assembly"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"721\" class=\"elementor elementor-721\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-aa23eb7 e-con-full e-flex e-con e-parent\" data-id=\"aa23eb7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f7391c7 elementor-widget elementor-widget-html\" data-id=\"f7391c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<!--\r\n  EliteBlocc \u2014 System Assembly Page\r\n  Elementor HTML Widget \u2014 v1.2\r\n  \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\r\n  CHANGES v1.2 (current)\r\n  \u2022 Hero wall cross-section corrected to verified 4-zone anatomy:\r\n    WC 45mm | EPS 200mm | RC 150mm | WC 45mm = 440mm total\r\n    (EPS is the dominant zone at 45.5% \u2014 cold exterior side of RC core)\r\n  \u2022 Added ruler, key\/legend, and stat strip to wall diagram\r\n  \u2022 Layer tabs reduced from 7 to 6 matching the anatomy\r\n  \u2022 Layer tab panel gains .eb-sa-lp-dim element (wired in JS v1.2)\r\n  \u2022 FAQ updated \u2014 anatomy and EPS position questions added\r\n  \u2022 Construction sequence copy updated from installation manual\r\n  \u2022 Staging URLs applied to all hrefs\r\n  \u2022 data-sa-stagger duplicate attribute removed\r\n  \u2022 Section IDs added: principle, applications\r\n  \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\r\n  DEPENDENCIES\r\n  CSS: assets\/css\/pages\/eb-system-assembly.css  (enqueue-assets.php \u00a712)\r\n  JS:  assets\/js\/pages\/eb-system-assembly.js    (enqueue-assets.php \u00a712)\r\n  Slug: system-assembly\r\n  \u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\r\n-->\r\n<div id=\"eb-sa-wrap\">\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S1 \u2014 HERO [DARK]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-hero\" aria-labelledby=\"eb-sa-h1\">\r\n  <div class=\"eb-sa-hero__rule\"   aria-hidden=\"true\"><\/div>\r\n  <div class=\"eb-sa-hero__glow-a\" aria-hidden=\"true\"><\/div>\r\n  <div class=\"eb-sa-hero__glow-b\" aria-hidden=\"true\"><\/div>\r\n  <div class=\"eb-sa-hero__inner\">\r\n\r\n    <div class=\"eb-sa-hero__text\">\r\n      <div class=\"eb-sa-eyebrow\">\r\n        <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n        System Assembly\r\n      <\/div>\r\n      <h1 class=\"eb-sa-hero__h1\" id=\"eb-sa-h1\">\r\n        One Wall System.<br>\r\n        <span class=\"eb-sa-em\">Multiple Functions.<\/span><br>\r\n        Built as One Assembly.\r\n      <\/h1>\r\n      <p class=\"eb-sa-hero__sub\">\r\n        Elite Blocc brings structure, insulation, fire performance, acoustic mass and construction efficiency into one coordinated wall system \u2014 reducing the number of separate layers, trades and interfaces normally required on site.\r\n      <\/p>\r\n      <p class=\"eb-sa-hero__support\">\r\n        Instead of building a wall in disconnected stages, the system uses wood-cement permanent formwork, integrated insulation and a reinforced concrete core to create a robust structural envelope ready for direct finishing.\r\n      <\/p>\r\n      <div class=\"eb-sa-ctas\">\r\n        <a href=\"#wall-build-up\" class=\"eb-sa-btn eb-sa-btn--primary\">\r\n          Explore the Build-Up <span class=\"eb-sa-btn-arr\">\u2193<\/span>\r\n        <\/a>\r\n        <a href=\"https:\/\/www.eliteblocc.com\/staging.v2\/technical-hub\/\" class=\"eb-sa-btn eb-sa-btn--secondary-dark\">\r\n          View Technical Hub <span class=\"eb-sa-btn-arr\">\u2192<\/span>\r\n        <\/a>\r\n        <a href=\"https:\/\/www.eliteblocc.com\/staging.v2\/download-centre\/\" class=\"eb-sa-btn eb-sa-btn--tertiary\">\r\n          Download Brochure\r\n        <\/a>\r\n      <\/div>\r\n    <\/div>\r\n\r\n    <div class=\"eb-sa-hero__wall-wrap\" aria-label=\"Interactive wall cross-section \u2014 HDIII 44\/20\">\r\n      <div class=\"eb-sa-wall-panel\">\r\n        <div class=\"eb-sa-wall-panel__label\">HDIII 44\/20 \u2014 WALL CROSS-SECTION<\/div>\r\n\r\n        <!--\r\n          VERIFIED ANATOMY \u2014 CSV source: PDF-HDIII-44-20\r\n          WC 45mm | EPS 200mm | RC 150mm | WC 45mm = 440mm total\r\n          EPS (200mm) = 45.5% \u2014 dominant zone \u2014 cold exterior side of RC core\r\n          Flex values map 1:1 to mm for pixel-accurate proportions.\r\n          JS reads data-layer-* attributes to populate the info panel.\r\n        -->\r\n        <div class=\"eb-sa-wall\" role=\"group\" aria-label=\"HDIII 44\/20 wall assembly \u2014 hover each zone to explore\">\r\n\r\n          <!-- RENDER (thin, decorative \u2014 not part of 440mm block depth) -->\r\n          <div class=\"eb-sa-wall-layer eb-sa-wl--rnd\" tabindex=\"0\"\r\n               data-layer-name=\"External Render \/ Finish\"\r\n               data-layer-tag=\"Weather-facing finish\"\r\n               data-layer-dim=\"Applied finish \u2014 not part of the 440 mm structural block\"\r\n               data-layer-desc=\"External render or protective finish applied to the outer WC face. Provides the weather-facing architectural surface. Render type and thickness are project-specific.\">\r\n            <div class=\"eb-sa-wl-lbl\" aria-hidden=\"true\"><strong>Render<\/strong><span>Applied<\/span><\/div>\r\n          <\/div>\r\n\r\n          <!-- WC OUTER: 45mm \/ 10.2% -->\r\n          <div class=\"eb-sa-wall-layer eb-sa-wl--wco\" tabindex=\"0\"\r\n               data-layer-name=\"Wood-Cement Formwork \u2014 Outer Shell\"\r\n               data-layer-tag=\"Permanent outer formwork \u00b7 45 mm\"\r\n               data-layer-dim=\"45 mm \u00b7 10.2% of 440 mm total depth\"\r\n               data-layer-desc=\"The 45 mm outer WC shell is the permanent external face of the block. Moisture-resistant, vapour-permeable and a stable substrate for external finishes. Retains the EPS insert and acts as permanent formwork for the concrete pour.\">\r\n            <div class=\"eb-sa-wl-lbl\" aria-hidden=\"true\"><strong>WC Outer<\/strong><span>45 mm<\/span><\/div>\r\n          <\/div>\r\n\r\n          <!-- EPS: 200mm \/ 45.5% \u2014 DOMINANT ZONE -->\r\n          <div class=\"eb-sa-wall-layer eb-sa-wl--eps\" tabindex=\"0\"\r\n               data-layer-name=\"EPS Insulation \u2014 Neopor\u00ae BMBcert\"\r\n               data-layer-tag=\"Graphite EPS \u00b7 200 mm \u2014 dominant zone\"\r\n               data-layer-dim=\"200 mm \u00b7 45.5% of 440 mm \u2014 cold exterior side of RC core\"\r\n               data-layer-desc=\"200 mm of BASF Neopor\u00ae BMBcert graphite-enhanced EPS \u2014 the largest single zone. Factory-integrated; no separate site installation required. Positioned on the cold exterior side of the RC core. Source: Isotex technical data sheet PDF-HDIII-44-20. 2D U-value: 0.13 W\/m\u00b2K.\">\r\n            <div class=\"eb-sa-wl-lbl\" aria-hidden=\"true\"><strong>EPS 200 mm<\/strong><span>Neopor\u00ae BMBcert<\/span><\/div>\r\n          <\/div>\r\n\r\n          <!-- RC: 150mm \/ 34.1% -->\r\n          <div class=\"eb-sa-wall-layer eb-sa-wl--rc\" tabindex=\"0\"\r\n               data-layer-name=\"Reinforced Concrete Structural Core\"\r\n               data-layer-tag=\"Primary structural element \u00b7 150 mm\"\r\n               data-layer-dim=\"150 mm \u00b7 34.1% of 440 mm total depth\"\r\n               data-layer-desc=\"Poured in situ after reinforcement is placed. Provides the primary structural strength. Concrete minimum S4 consistency class; aggregate below 16 mm. Reinforcement design and specification must always follow the project engineer's structural design and applicable standards.\">\r\n            <div class=\"eb-sa-wl-lbl\" aria-hidden=\"true\"><strong>RC 150 mm<\/strong><span>Structural core<\/span><\/div>\r\n          <\/div>\r\n\r\n          <!-- WC INNER: 45mm \/ 10.2% -->\r\n          <div class=\"eb-sa-wall-layer eb-sa-wl--wco\" tabindex=\"0\"\r\n               data-layer-name=\"Wood-Cement Formwork \u2014 Inner Shell\"\r\n               data-layer-tag=\"Inner face \u00b7 45 mm\"\r\n               data-layer-dim=\"45 mm \u00b7 10.2% of 440 mm total depth\"\r\n               data-layer-desc=\"The 45 mm inner WC face provides a stable, breathable, direct substrate for internal finishes. Sits directly against the RC core. Plaster or render can be applied directly \u2014 no additional boarding is typically required.\">\r\n            <div class=\"eb-sa-wl-lbl\" aria-hidden=\"true\"><strong>WC Inner<\/strong><span>45 mm<\/span><\/div>\r\n          <\/div>\r\n\r\n          <!-- PLASTER (thin, decorative) -->\r\n          <div class=\"eb-sa-wall-layer eb-sa-wl--rnd\" tabindex=\"0\"\r\n               data-layer-name=\"Internal Finish \/ Plaster\"\r\n               data-layer-tag=\"Direct-finish substrate\"\r\n               data-layer-dim=\"Applied finish \u2014 not part of the 440 mm structural block\"\r\n               data-layer-desc=\"Internal render or plaster applied directly to the inner WC face. Apply only to dry surfaces. For build-up exceeding 20 mm use two coats separated by at least 28 days.\">\r\n            <div class=\"eb-sa-wl-lbl\" aria-hidden=\"true\"><strong>Plaster<\/strong><span>Applied<\/span><\/div>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <!-- DIMENSION RULER \u2014 flex proportions match the wall layers above -->\r\n        <div class=\"eb-sa-wall-ruler\" aria-hidden=\"true\">\r\n          <div class=\"eb-sa-xr eb-sa-xr--rnd\"><\/div>\r\n          <div class=\"eb-sa-xr eb-sa-xr--wc\">45<\/div>\r\n          <div class=\"eb-sa-xr eb-sa-xr--eps\">200 mm EPS<\/div>\r\n          <div class=\"eb-sa-xr eb-sa-xr--rc\">150 mm RC<\/div>\r\n          <div class=\"eb-sa-xr eb-sa-xr--wc\">45<\/div>\r\n          <div class=\"eb-sa-xr eb-sa-xr--rnd\"><\/div>\r\n        <\/div>\r\n\r\n        <!-- KEY -->\r\n        <div class=\"eb-sa-wall-key\" aria-label=\"Cross-section colour key\">\r\n          <div class=\"eb-sa-wk\">\r\n            <div class=\"eb-sa-wk-dot\" style=\"background:#7a4f25\" aria-hidden=\"true\"><\/div>\r\n            Wood-cement (WC) \u00b7 45 mm each\r\n          <\/div>\r\n          <div class=\"eb-sa-wk\">\r\n            <div class=\"eb-sa-wk-dot\" style=\"background:rgba(16,185,129,.55)\" aria-hidden=\"true\"><\/div>\r\n            EPS insulation \u00b7 200 mm\r\n          <\/div>\r\n          <div class=\"eb-sa-wk\">\r\n            <div class=\"eb-sa-wk-dot\" style=\"background:rgba(59,130,246,.55)\" aria-hidden=\"true\"><\/div>\r\n            RC core \u00b7 150 mm\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <!-- WALL INFO PANEL \u2014 updated by JS on hover \/ focus -->\r\n        <div class=\"eb-sa-wall-info\" aria-live=\"polite\" aria-atomic=\"true\">\r\n          <div class=\"eb-sa-wi-tag\"  id=\"eb-sa-wi-tag\">Hover a zone to explore<\/div>\r\n          <div class=\"eb-sa-wi-name\" id=\"eb-sa-wi-name\">HDIII 44\/20 \u2014 440 mm wall system<\/div>\r\n          <div class=\"eb-sa-wi-desc\" id=\"eb-sa-wi-desc\">\r\n            The EPS insulation (200 mm) is the dominant zone, positioned on the cold exterior side of the RC structural core. WC shells (45 mm each) form the inner and outer faces.\r\n          <\/div>\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S2 \u2014 CORE PRINCIPLE [LIGHT CREAM]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-principle\" id=\"principle\">\r\n  <div class=\"eb-sa-principle__inner\">\r\n    <div class=\"eb-sa-eyebrow\" data-sa-reveal>\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      The Principle\r\n    <\/div>\r\n    <h2 class=\"eb-sa-h2 eb-sa-h2--light\" style=\"font-size:clamp(22px,2.8vw,36px);max-width:640px\" data-sa-reveal>\r\n      The Wall Is Not Assembled From Risk.<br>\r\n      <span class=\"eb-sa-em\">It Is Engineered as a System.<\/span>\r\n    <\/h2>\r\n    <div class=\"eb-sa-principle__grid\">\r\n      <div class=\"eb-sa-principle__copy\" data-sa-reveal-left>\r\n        <p>Traditional external walls often rely on multiple independent components \u2014 structural blockwork, insulation, cavity detailing, wall ties, membranes, battens, boards, fire-stopping and finish layers. Each interface is another point where quality, sequencing or workmanship can affect final performance.<\/p>\r\n        <p>The Elite Blocc system takes a different approach. Structure, insulation and permanent formwork are coordinated within one assembly, reducing the number of separate operations and producing a more predictable performance outcome. The 200 mm EPS insulation is factory-integrated on the cold exterior side of the RC core \u2014 the thermally correct position \u2014 and requires no separate site installation.<\/p>\r\n        <p>The result is a construction method designed to reduce envelope complexity while improving confidence in the completed wall system.<\/p>\r\n      <\/div>\r\n      <div class=\"eb-sa-key-points\" data-sa-reveal-right>\r\n        <div class=\"eb-sa-kp\"><span class=\"eb-sa-kp__dot\" aria-hidden=\"true\"><\/span><span class=\"eb-sa-kp__text\">Integrated structural concrete core<\/span><\/div>\r\n        <div class=\"eb-sa-kp\"><span class=\"eb-sa-kp__dot\" aria-hidden=\"true\"><\/span><span class=\"eb-sa-kp__text\">200 mm EPS on the cold side \u2014 factory-integrated, not site-applied<\/span><\/div>\r\n        <div class=\"eb-sa-kp\"><span class=\"eb-sa-kp__dot\" aria-hidden=\"true\"><\/span><span class=\"eb-sa-kp__text\">Permanent wood-cement formwork on both faces<\/span><\/div>\r\n        <div class=\"eb-sa-kp\"><span class=\"eb-sa-kp__dot\" aria-hidden=\"true\"><\/span><span class=\"eb-sa-kp__text\">Direct internal and external finishing potential<\/span><\/div>\r\n        <div class=\"eb-sa-kp\"><span class=\"eb-sa-kp__dot\" aria-hidden=\"true\"><\/span><span class=\"eb-sa-kp__text\">Reduced dependency on multiple trades and sequencing stages<\/span><\/div>\r\n        <div class=\"eb-sa-kp\"><span class=\"eb-sa-kp__dot\" aria-hidden=\"true\"><\/span><span class=\"eb-sa-kp__text\">Technical documentation available to support specification<\/span><\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S3 \u2014 WALL BUILD-UP [DARK + EMERALD]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-buildup\" id=\"wall-build-up\">\r\n  <div class=\"eb-sa-buildup__glow-a\" aria-hidden=\"true\"><\/div>\r\n  <div class=\"eb-sa-buildup__glow-b\" aria-hidden=\"true\"><\/div>\r\n  <div class=\"eb-sa-buildup__inner\">\r\n    <div class=\"eb-sa-eyebrow\" data-sa-reveal>\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Wall Build-Up\r\n    <\/div>\r\n    <h2 class=\"eb-sa-h2\" style=\"font-size:clamp(22px,2.8vw,36px)\" data-sa-reveal>\r\n      From External Finish <span class=\"eb-sa-em\">to Internal Surface<\/span>\r\n    <\/h2>\r\n    <p class=\"eb-sa-buildup__intro\" data-sa-reveal>\r\n      The HDIII 44\/20 wall assembly has four structural zones plus applied finishes. Each zone has a distinct role. The performance comes from how they work together as one engineered system.\r\n    <\/p>\r\n    <div class=\"eb-sa-buildup__layout\">\r\n      <div class=\"eb-sa-layer-tabs\" role=\"tablist\" aria-label=\"Wall assembly layers\">\r\n        <button class=\"eb-sa-layer-tab is-active\" role=\"tab\" aria-selected=\"true\"  aria-controls=\"eb-sa-layer-panel\" data-i=\"0\">\r\n          <span class=\"eb-sa-lt-swatch\" style=\"background:rgba(200,210,200,.35)\" aria-hidden=\"true\"><\/span>\r\n          <span class=\"eb-sa-lt-num\">01<\/span><span class=\"eb-sa-lt-name\">External Finish<\/span>\r\n        <\/button>\r\n        <button class=\"eb-sa-layer-tab\" role=\"tab\" aria-selected=\"false\" aria-controls=\"eb-sa-layer-panel\" data-i=\"1\">\r\n          <span class=\"eb-sa-lt-swatch\" style=\"background:#7a4f25\" aria-hidden=\"true\"><\/span>\r\n          <span class=\"eb-sa-lt-num\">02<\/span><span class=\"eb-sa-lt-name\">WC Outer (45 mm)<\/span>\r\n        <\/button>\r\n        <button class=\"eb-sa-layer-tab\" role=\"tab\" aria-selected=\"false\" aria-controls=\"eb-sa-layer-panel\" data-i=\"2\">\r\n          <span class=\"eb-sa-lt-swatch\" style=\"background:rgba(16,185,129,.55)\" aria-hidden=\"true\"><\/span>\r\n          <span class=\"eb-sa-lt-num\">03<\/span><span class=\"eb-sa-lt-name\">EPS Insulation (200 mm)<\/span>\r\n        <\/button>\r\n        <button class=\"eb-sa-layer-tab\" role=\"tab\" aria-selected=\"false\" aria-controls=\"eb-sa-layer-panel\" data-i=\"3\">\r\n          <span class=\"eb-sa-lt-swatch\" style=\"background:rgba(59,130,246,.55)\" aria-hidden=\"true\"><\/span>\r\n          <span class=\"eb-sa-lt-num\">04<\/span><span class=\"eb-sa-lt-name\">RC Structural Core (150 mm)<\/span>\r\n        <\/button>\r\n        <button class=\"eb-sa-layer-tab\" role=\"tab\" aria-selected=\"false\" aria-controls=\"eb-sa-layer-panel\" data-i=\"4\">\r\n          <span class=\"eb-sa-lt-swatch\" style=\"background:#7a4f25\" aria-hidden=\"true\"><\/span>\r\n          <span class=\"eb-sa-lt-num\">05<\/span><span class=\"eb-sa-lt-name\">WC Inner (45 mm)<\/span>\r\n        <\/button>\r\n        <button class=\"eb-sa-layer-tab\" role=\"tab\" aria-selected=\"false\" aria-controls=\"eb-sa-layer-panel\" data-i=\"5\">\r\n          <span class=\"eb-sa-lt-swatch\" style=\"background:rgba(200,210,200,.35)\" aria-hidden=\"true\"><\/span>\r\n          <span class=\"eb-sa-lt-num\">06<\/span><span class=\"eb-sa-lt-name\">Internal Finish<\/span>\r\n        <\/button>\r\n      <\/div>\r\n      <div class=\"eb-sa-layer-panel\" id=\"eb-sa-layer-panel\" role=\"tabpanel\">\r\n        <div class=\"eb-sa-lp-num\">LAYER 01 \/ 06<\/div>\r\n        <div class=\"eb-sa-lp-title\">External Render \/ Protective Finish<\/div>\r\n        <p class=\"eb-sa-lp-desc\">Applied to the outer face of the WC shell. Provides the weather-facing architectural surface and protects the assembly from environmental exposure. Render type, thickness and primer requirements are project-specific.<\/p>\r\n        <span class=\"eb-sa-lp-badge\">\r\n          <span class=\"eb-sa-lp-badge-dot\" aria-hidden=\"true\"><\/span>\r\n          <span>Weather-facing finish<\/span>\r\n        <\/span>\r\n        <div class=\"eb-sa-lp-dim\">Not part of the 440 mm structural block depth<\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S4 \u2014 CONSTRUCTION SEQUENCE [LIGHT TINTED]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-sequence\" id=\"construction-sequence\">\r\n  <div class=\"eb-sa-sequence__inner\">\r\n    <div class=\"eb-sa-eyebrow\" data-sa-reveal>\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Construction Sequence\r\n    <\/div>\r\n    <h2 class=\"eb-sa-h2 eb-sa-h2--light\" style=\"font-size:clamp(22px,2.8vw,36px)\" data-sa-reveal>\r\n      A Clearer Route <span class=\"eb-sa-em\">From Foundation to Finished Wall<\/span>\r\n    <\/h2>\r\n    <p class=\"eb-sa-sequence__intro\" data-sa-reveal>\r\n      The system is designed to simplify the wall build process. Fewer separate layers means fewer separate operations and a more direct route to structural enclosure.\r\n    <\/p>\r\n    <div class=\"eb-sa-seq-track\">\r\n      <div class=\"eb-sa-seq-line\" aria-hidden=\"true\"><\/div>\r\n      <div class=\"eb-sa-seq-steps\" data-sa-stagger=\"0.1\">\r\n        <div class=\"eb-sa-seq-step\" data-sa-stagger-item>\r\n          <div class=\"eb-sa-seq-node\" aria-hidden=\"true\">01<\/div>\r\n          <div class=\"eb-sa-seq-card\">\r\n            <div class=\"eb-sa-seq-title\">Set Out and Prepare the Base<\/div>\r\n            <div class=\"eb-sa-seq-body\">Set the wall line from structural drawings. Lay the first course on two mortar beds positioned only under the block walls \u2014 a full-width mortar bed is avoided because mortar has lower compression resistance than concrete. Accuracy at this stage governs the quality of the entire assembly.<\/div>\r\n          <\/div>\r\n        <\/div>\r\n        <div class=\"eb-sa-seq-step\" data-sa-stagger-item>\r\n          <div class=\"eb-sa-seq-node\" aria-hidden=\"true\">02<\/div>\r\n          <div class=\"eb-sa-seq-card\">\r\n            <div class=\"eb-sa-seq-title\">Dry-Stack the Blocks<\/div>\r\n            <div class=\"eb-sa-seq-body\">Subsequent courses are dry-laid, starting from corner or UNI blocks. Stagger courses by half a block. Keep blocks tightly closed \u2014 Isotex does not recommend insulating foam for compensating gaps, as this can create thermal or acoustic bridges.<\/div>\r\n          <\/div>\r\n        <\/div>\r\n        <div class=\"eb-sa-seq-step\" data-sa-stagger-item>\r\n          <div class=\"eb-sa-seq-node\" aria-hidden=\"true\">03<\/div>\r\n          <div class=\"eb-sa-seq-card\">\r\n            <div class=\"eb-sa-seq-title\">Place Reinforcement<\/div>\r\n            <div class=\"eb-sa-seq-body\">Horizontal bars rest in the block lunettes with spacers at every course. Vertical bars are positioned centrally within the cavity. Reinforcement laps must be at least 50% greater than required by applicable standards. Reinforcement specification must always follow the project engineer's structural design.<\/div>\r\n          <\/div>\r\n        <\/div>\r\n        <div class=\"eb-sa-seq-step\" data-sa-stagger-item>\r\n          <div class=\"eb-sa-seq-node\" aria-hidden=\"true\">04<\/div>\r\n          <div class=\"eb-sa-seq-card\">\r\n            <div class=\"eb-sa-seq-title\">Pour the Concrete Core<\/div>\r\n            <div class=\"eb-sa-seq-body\">After approximately 6 courses (1500 mm), fill the cavities with concrete. Minimum consistency class S4; aggregate below 16 mm. Start from perimeter walls approximately 1000 mm from corners and shoulders to reduce localised pressure. Vibrate with a small poker to ensure complete fill.<\/div>\r\n          <\/div>\r\n        <\/div>\r\n        <div class=\"eb-sa-seq-step\" data-sa-stagger-item>\r\n          <div class=\"eb-sa-seq-node\" aria-hidden=\"true\">05<\/div>\r\n          <div class=\"eb-sa-seq-card\">\r\n            <div class=\"eb-sa-seq-title\">Apply Finishes<\/div>\r\n            <div class=\"eb-sa-seq-body\">Apply plaster only to dry surfaces. Avoid frozen walls, wet surfaces or walls with unset concrete. The wood-cement face is the direct substrate \u2014 no additional boarding is typically required before plastering. For build-up exceeding 20 mm use two coats separated by at least 28 days.<\/div>\r\n          <\/div>\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S5 \u2014 COMPARISON [SPLIT]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-compare\" aria-label=\"Comparison: traditional versus Elite Blocc system approach\">\r\n  <div class=\"eb-sa-compare__trad\" data-sa-reveal-left>\r\n    <div class=\"eb-sa-eyebrow eb-sa-eyebrow--muted\">\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Traditional Approach\r\n    <\/div>\r\n    <h2 class=\"eb-sa-compare__heading\" style=\"color:#6b7d6e\">Traditional<br>Wall Approach<\/h2>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Structural blockwork as a separate element<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Insulation installed separately \u2014 risk of gaps<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Multiple cavity and interface details to manage<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Fire-stopping specified and installed separately<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Multiple trades and sequencing dependencies<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Performance sensitive to workmanship at each interface<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Envelope performance reliant on site variation control<\/div>\r\n  <\/div>\r\n  <div class=\"eb-sa-compare__eb\" data-sa-reveal-right>\r\n    <div class=\"eb-sa-eyebrow\">\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Elite Blocc Approach\r\n    <\/div>\r\n    <h2 class=\"eb-sa-compare__heading\">Coordinated<br><span style=\"color:#F5F4F2\">System Assembly<\/span><\/h2>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Structure and insulation coordinated in one manufactured block<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>EPS integrated on the cold side \u2014 no site installation risk<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Permanent WC formwork replaces separate shuttering<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Reduced number of separate build stages on site<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Clearer installation logic from first course to pour<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Performance route easier to verify and inspect<\/div>\r\n    <div class=\"eb-sa-compare-item\"><span class=\"eb-sa-ci-dot\" aria-hidden=\"true\"><\/span>Technical documentation supports specification<\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S6 \u2014 PERFORMANCE [LIGHT]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-performance\" id=\"performance-logic\">\r\n  <div class=\"eb-sa-performance__inner\">\r\n    <div class=\"eb-sa-eyebrow\" data-sa-reveal>\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Performance Logic\r\n    <\/div>\r\n    <h2 class=\"eb-sa-h2 eb-sa-h2--light\" style=\"font-size:clamp(22px,2.8vw,36px)\" data-sa-reveal>\r\n      Performance Comes From <span class=\"eb-sa-em\">the Assembly.<\/span>\r\n    <\/h2>\r\n    <p class=\"eb-sa-performance__intro\" data-sa-reveal>\r\n      The system's value comes from the relationship between mass, insulation position, structural continuity and certified documentation. Values below are specific to HDIII 44\/20 and sourced from supplied Isotex technical data sheets.\r\n    <\/p>\r\n    <div class=\"eb-sa-perf-grid\">\r\n      <div class=\"eb-sa-perf-card\">\r\n        <h3 class=\"eb-sa-pc-title\">Structural Strength<\/h3>\r\n        <p class=\"eb-sa-pc-body\">The 150 mm reinforced concrete core provides the primary structural capacity. Wall geometry, reinforcement schedule and concrete grade must be confirmed by the project engineer to the applicable structural standard for the project location.<\/p>\r\n      <\/div>\r\n      <div class=\"eb-sa-perf-card\">\r\n        <h3 class=\"eb-sa-pc-title\">Thermal Performance<\/h3>\r\n        <p class=\"eb-sa-pc-body\">200 mm of Neopor\u00ae BMBcert EPS is positioned on the cold exterior side of the RC core \u2014 the thermally correct location for an external wall. No separately installed insulation layer is required. Published 2D U-value: 0.13 W\/m\u00b2K for HDIII 44\/20.<\/p>\r\n      <\/div>\r\n      <div class=\"eb-sa-perf-card\">\r\n        <h3 class=\"eb-sa-pc-title\">Fire Performance<\/h3>\r\n        <p class=\"eb-sa-pc-body\">Fire resistance must be assessed by product type, wall build-up and certification scope. REI 120 is the verified rating for the HDIII wall system per supplied Isotex fire certification. Do not apply floor fire ratings to wall assemblies.<\/p>\r\n      <\/div>\r\n      <div class=\"eb-sa-perf-card\">\r\n        <h3 class=\"eb-sa-pc-title\">Acoustic Comfort<\/h3>\r\n        <p class=\"eb-sa-pc-body\">The combination of wall mass, concrete core and wood-cement faces contributes to sound insulation. Published single-partition acoustic value for HDIII 44\/20: 53 dB Rw. Double-partition values are listed separately \u2014 do not conflate the two figures.<\/p>\r\n      <\/div>\r\n      <div class=\"eb-sa-perf-card\">\r\n        <h3 class=\"eb-sa-pc-title\">Durability<\/h3>\r\n        <p class=\"eb-sa-pc-body\">The wood-cement shells become a permanent part of the finished wall \u2014 there is no shuttering to strip. The WC and concrete core create a robust, long-term wall assembly suited to exposed and demanding climatic conditions.<\/p>\r\n      <\/div>\r\n      <div class=\"eb-sa-perf-card\">\r\n        <h3 class=\"eb-sa-pc-title\">Programme Efficiency<\/h3>\r\n        <p class=\"eb-sa-pc-body\">By combining structural, insulation and formwork functions into one block, the system reduces the number of discrete operations required to reach a complete, insulated, structurally resolved wall ready for finishing.<\/p>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S7 \u2014 APPLICATIONS [DARK GRID]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-applications\" id=\"applications\">\r\n  <div class=\"eb-sa-apps-glow-a\" aria-hidden=\"true\"><\/div>\r\n  <div class=\"eb-sa-apps-glow-b\" aria-hidden=\"true\"><\/div>\r\n  <div class=\"eb-sa-applications__inner\">\r\n    <div class=\"eb-sa-eyebrow\" data-sa-reveal>\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Applications\r\n    <\/div>\r\n    <h2 class=\"eb-sa-h2\" style=\"font-size:clamp(22px,2.8vw,36px)\" data-sa-reveal>\r\n      Designed for Projects <span class=\"eb-sa-em\">Where Certainty Matters<\/span>\r\n    <\/h2>\r\n    <p class=\"eb-sa-applications__intro\" data-sa-reveal>\r\n      Elite Blocc suits projects where wall performance, build predictability and long-term durability are central to the design brief. The system is used across residential, hospitality, commercial and development sectors in the Dominican Republic, the Caribbean and the UK.\r\n    <\/p>\r\n    <div class=\"eb-sa-app-grid\">\r\n      <div class=\"eb-sa-app-card\"><h3 class=\"eb-sa-app-title\">Private Homes and Villas<\/h3><p class=\"eb-sa-app-body\">Thermal comfort, acoustic mass and a high-quality building envelope \u2014 particularly suited to warm-climate residential construction in the Caribbean and Dominican Republic.<\/p><\/div>\r\n      <div class=\"eb-sa-app-card\"><h3 class=\"eb-sa-app-title\">Residential Developments<\/h3><p class=\"eb-sa-app-body\">A repeatable wall system with documented performance and clearer specification control across multiple units or phases.<\/p><\/div>\r\n      <div class=\"eb-sa-app-card\"><h3 class=\"eb-sa-app-title\">Hotels and Hospitality<\/h3><p class=\"eb-sa-app-body\">Speed to enclosure, acoustic separation between spaces, thermal performance and robust construction suited to heavy use.<\/p><\/div>\r\n      <div class=\"eb-sa-app-card\"><h3 class=\"eb-sa-app-title\">Commercial Buildings<\/h3><p class=\"eb-sa-app-body\">Offices, mixed-use and commercial structures requiring a high-performance, specification-backed external wall strategy.<\/p><\/div>\r\n      <div class=\"eb-sa-app-card\"><h3 class=\"eb-sa-app-title\">Coastal and Exposed Locations<\/h3><p class=\"eb-sa-app-body\">The concrete core and wood-cement faces provide resilience in exposed environments where durability and specification control are priorities.<\/p><\/div>\r\n      <div class=\"eb-sa-app-card\"><h3 class=\"eb-sa-app-title\">Caribbean and Warm Climate<\/h3><p class=\"eb-sa-app-body\">Thermal performance, structural design appropriate to the regional climate, and efficient delivery supported by Elite Blocc's Santo Domingo base.<\/p><\/div>\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S8 \u2014 SPECIFICATION NOTE [LIGHT GOLD]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-spec\" id=\"specification-note\">\r\n  <div class=\"eb-sa-spec__header\">\r\n    <div class=\"eb-sa-eyebrow eb-sa-eyebrow--gold\" data-sa-reveal>\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Specification Note\r\n    <\/div>\r\n    <h2 class=\"eb-sa-h2 eb-sa-h2--gold\" style=\"font-size:clamp(20px,2.4vw,30px)\" data-sa-reveal>\r\n      Every Project Still Requires <span class=\"eb-sa-gold\">Correct Design and Engineering.<\/span>\r\n    <\/h2>\r\n  <\/div>\r\n  <div class=\"eb-sa-spec__inner\">\r\n    <div class=\"eb-sa-spec__copy\" data-sa-reveal-left>\r\n      <p>Elite Blocc provides a high-performance wall system with published technical documentation. Final specification must always be reviewed against the selected product, project location, structural design, fire strategy, acoustic requirements, thermal targets and applicable local building regulations.<\/p>\r\n      <p>For projects in seismic, hurricane-prone, coastal or high-exposure environments, the wall assembly and structural design must be confirmed by the project engineer and relevant design team before construction commences.<\/p>\r\n    <\/div>\r\n    <div class=\"eb-sa-spec-note\" role=\"note\" data-sa-reveal-right>\r\n      <p><strong>Technical note:<\/strong> Published performance values are specific to HDIII 44\/20 and sourced from supplied Isotex technical documentation. Values vary between products \u2014 always refer to the correct product datasheet for the selected configuration. Final product selection, structural design, fire strategy, acoustic design, thermal modelling and compliance checks must be confirmed by the appointed project professionals and relevant authorities.<\/p>\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S9 \u2014 FAQ [DARK + EMERALD]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-faq\" id=\"faqs\">\r\n  <div class=\"eb-sa-faq__inner\">\r\n    <div class=\"eb-sa-eyebrow\" data-sa-reveal>\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Frequently Asked\r\n    <\/div>\r\n    <h2 class=\"eb-sa-h2\" style=\"font-size:clamp(22px,2.8vw,36px)\" data-sa-reveal>System Assembly FAQs<\/h2>\r\n    <div class=\"eb-sa-faq-list\" data-sa-stagger=\"0.06\">\r\n\r\n      <div class=\"eb-sa-faq-item\" data-sa-stagger-item>\r\n        <button class=\"eb-sa-faq-q\" aria-expanded=\"false\">\r\n          What is the correct layer anatomy for HDIII 44\/20?\r\n          <span class=\"eb-sa-faq-icon\" aria-hidden=\"true\">+<\/span>\r\n        <\/button>\r\n        <div class=\"eb-sa-faq-a\" role=\"region\">\r\n          The HDIII 44\/20 has four structural zones: WC outer shell (45 mm) \u00b7 EPS insulation (200 mm) \u00b7 RC structural core (150 mm) \u00b7 WC inner shell (45 mm) = 440 mm total. The EPS insulation is the dominant zone at 45.5% of total wall depth, positioned on the cold exterior side of the concrete core. Source: Isotex technical data sheet PDF-HDIII-44-20.\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <div class=\"eb-sa-faq-item\" data-sa-stagger-item>\r\n        <button class=\"eb-sa-faq-q\" aria-expanded=\"false\">\r\n          Is the insulation on both sides of the RC core?\r\n          <span class=\"eb-sa-faq-icon\" aria-hidden=\"true\">+<\/span>\r\n        <\/button>\r\n        <div class=\"eb-sa-faq-a\" role=\"region\">\r\n          No. In the HDIII system the EPS insulation sits as one zone between the outer WC shell and the RC structural core. The inner WC shell sits directly against the concrete. This positions all 200 mm of insulation on the cold exterior side \u2014 the thermally correct placement for an external wall system.\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <div class=\"eb-sa-faq-item\" data-sa-stagger-item>\r\n        <button class=\"eb-sa-faq-q\" aria-expanded=\"false\">\r\n          Is Elite Blocc just another block system?\r\n          <span class=\"eb-sa-faq-icon\" aria-hidden=\"true\">+<\/span>\r\n        <\/button>\r\n        <div class=\"eb-sa-faq-a\" role=\"region\">\r\n          No. The value is in the full wall assembly. The system combines permanent wood-cement formwork, factory-integrated EPS insulation and a reinforced concrete core into one coordinated build method. The block is the starting point of the system, not the system itself.\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <div class=\"eb-sa-faq-item\" data-sa-stagger-item>\r\n        <button class=\"eb-sa-faq-q\" aria-expanded=\"false\">\r\n          What provides the structural strength?\r\n          <span class=\"eb-sa-faq-icon\" aria-hidden=\"true\">+<\/span>\r\n        <\/button>\r\n        <div class=\"eb-sa-faq-a\" role=\"region\">\r\n          The reinforced concrete core, poured in situ through the block cavities. Concrete consistency class should be not less than S4 with aggregate below 16 mm. Reinforcement design and concrete specification must always follow the project engineer's structural calculation and the applicable structural standards for the project location.\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <div class=\"eb-sa-faq-item\" data-sa-stagger-item>\r\n        <button class=\"eb-sa-faq-q\" aria-expanded=\"false\">\r\n          Can the wall be directly finished internally and externally?\r\n          <span class=\"eb-sa-faq-icon\" aria-hidden=\"true\">+<\/span>\r\n        <\/button>\r\n        <div class=\"eb-sa-faq-a\" role=\"region\">\r\n          Yes. The wood-cement faces on both sides are designed to receive plaster, render or dry-lining directly. Apply only to dry surfaces; avoid frozen conditions or unset concrete. For plaster build-up exceeding 20 mm, use two coats separated by at least 28 days to prevent cracking or crazing.\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <div class=\"eb-sa-faq-item\" data-sa-stagger-item>\r\n        <button class=\"eb-sa-faq-q\" aria-expanded=\"false\">\r\n          Where do I find product datasheets and certification documents?\r\n          <span class=\"eb-sa-faq-icon\" aria-hidden=\"true\">+<\/span>\r\n        <\/button>\r\n        <div class=\"eb-sa-faq-a\" role=\"region\">\r\n          Technical datasheets, CE and ETA certification, BBA assessments, EPD documents and fire certification are available through the Elite Blocc Technical Hub and Download Centre. For project-specific technical support, contact the Elite Blocc team directly \u2014 a technical team, not a brochure, is behind every recommendation.\r\n        <\/div>\r\n      <\/div>\r\n\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\r\n     S10 \u2014 FINAL CTA [SPLIT]\r\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\r\n<section class=\"eb-sa-cta-final\" aria-label=\"Next steps\">\r\n  <div class=\"eb-sa-cta-final__light\" data-sa-reveal>\r\n    <div class=\"eb-sa-eyebrow\">\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Next Steps\r\n    <\/div>\r\n    <h2 class=\"eb-sa-cta-h\">Ready to Review the System for Your Project?<\/h2>\r\n    <p class=\"eb-sa-cta-sub\">Review the correct product family, wall build-up and technical documentation for your project requirements. Elite Blocc can advise on wall strategy and specification where project drawings are available.<\/p>\r\n    <div class=\"eb-sa-ctas eb-sa-ctas--col\">\r\n      <a href=\"https:\/\/www.eliteblocc.com\/staging.v2\/technical-hub\/\" class=\"eb-sa-btn eb-sa-btn--primary\">\r\n        View Technical Hub <span class=\"eb-sa-btn-arr\">\u2192<\/span>\r\n      <\/a>\r\n      <a href=\"https:\/\/www.eliteblocc.com\/staging.v2\/download-centre\/\" class=\"eb-sa-btn eb-sa-btn--secondary-light\">\r\n        Download Brochure <span class=\"eb-sa-btn-arr\">\u2193<\/span>\r\n      <\/a>\r\n      <a href=\"https:\/\/www.eliteblocc.com\/staging.v2\/contact\/\" class=\"eb-sa-btn eb-sa-btn--tertiary-light\">\r\n        Request Project Review\r\n      <\/a>\r\n    <\/div>\r\n    <p class=\"eb-sa-cta-reassure\">For projects with drawings available, Elite Blocc can review the wall strategy and advise on the appropriate product, reinforcement approach and technical documentation package.<\/p>\r\n  <\/div>\r\n  <div class=\"eb-sa-cta-final__dark\" data-sa-reveal>\r\n    <div class=\"eb-sa-eyebrow\">\r\n      <span class=\"eb-sa-ey-rule\" aria-hidden=\"true\"><\/span>\r\n      Explore Further\r\n    <\/div>\r\n    <h2 class=\"eb-sa-cta-h\">Explore the<br><span class=\"eb-sa-em\">Technical Hub<\/span><\/h2>\r\n    <p class=\"eb-sa-cta-sub\">Product datasheets, CE and ETA certification, EPD documents, BBA assessment, fire certification and system specifications \u2014 all in one place for specifiers, developers and contractors.<\/p>\r\n    <div class=\"eb-sa-ctas eb-sa-ctas--col\">\r\n      <a href=\"https:\/\/www.eliteblocc.com\/staging.v2\/technical-hub\/\" class=\"eb-sa-btn eb-sa-btn--primary\">\r\n        Technical Hub <span class=\"eb-sa-btn-arr\">\u2192<\/span>\r\n      <\/a>\r\n      <a href=\"https:\/\/www.eliteblocc.com\/staging.v2\/products-hub\/\" class=\"eb-sa-btn eb-sa-btn--secondary-dark\">\r\n        Products Hub <span class=\"eb-sa-btn-arr\">\u2192<\/span>\r\n      <\/a>\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n<\/div><!-- \/#eb-sa-wrap -->\r\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>System Assembly One Wall System. Multiple Functions. Built as One Assembly. Elite Blocc brings structure, insulation, fire performance, acoustic mass and construction efficiency into one coordinated wall system \u2014 reducing the number of separate layers, trades and interfaces normally required on site. Instead of building a wall in disconnected stages, the system uses wood-cement permanent [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"_acf_changed":false,"footnotes":""},"eb_product_family":[],"class_list":["post-721","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.eliteblocc.com\/staging.v2\/wp-json\/wp\/v2\/pages\/721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eliteblocc.com\/staging.v2\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.eliteblocc.com\/staging.v2\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.eliteblocc.com\/staging.v2\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eliteblocc.com\/staging.v2\/wp-json\/wp\/v2\/comments?post=721"}],"version-history":[{"count":0,"href":"https:\/\/www.eliteblocc.com\/staging.v2\/wp-json\/wp\/v2\/pages\/721\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.eliteblocc.com\/staging.v2\/wp-json\/wp\/v2\/media?parent=721"}],"wp:term":[{"taxonomy":"eb_product_family","embeddable":true,"href":"https:\/\/www.eliteblocc.com\/staging.v2\/wp-json\/wp\/v2\/eb_product_family?post=721"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}